Fuses Timed and rearmable circuit breakers manually 15A
    • Fuses Timed and rearmable circuit breakers manually 15A
    • Fuses Timed and rearmable circuit breakers manually 15A

    Fuses Timed and rearmable circuit breakers manually 15A

    223215
    Robert Lye

    fuses triggers triggers and rearmable manually 15a

    €17.25
    VAT included
    €14.38 VAT excluded
    LIVRAISON 24/48H
    Quantity
    In stock - Immediate delivery

     

      Delivery policy

    (edit with the Customer Reassurance module)

      Security policy

    (edit with the Customer Reassurance module)

      Return policy

    (edit with the Customer Reassurance module)

     

    Description
    Applications:
    - Protection against short circuits and overvoltages of electrical circuits.
    - They settle in place of the classic file fuses, in particular on the fuse holders and standard fuse boxes.
    - Unlike conventional fuses, they are rearmable and reusable.

    Advantages:
    - Protection of critical electrical circuits requiring a rapid discount of the fuse function after its breakup. (Example: opening roofs or window raising in snow or strong jelly, bus door blocking etc ...)
    - Protection and safety against the presence of electrical overvoltages on all types of vehicles thus avoiding the combustion of cables or insulating part of the main electrical circuit.
    - Avoid triggers by aging or untimely.
    - Almost unlimited lifespan.

    Domains of use:
    - Light and heavy vehicles 12 and 24 volts, including priority vehicles, troubleshooting or rescue, competition etc ...
    - Bus, public works, special vehicles with electrical equipment subject to high operating constraints.

    These circuit breakers can be triggered manually, then rearmed in the same way.
    Polar thermal circuit breaker of low footprint for vehicles. Punched in the classic fuse holders base.

    Examples of Applications:
    Protection of 12/24 volts DC on board and devices on road vehicles, boats and low -voltage installations.
    - Finding of breakdown in a circuit or a fuse box.
    -Mounted among others on Daimler-Benz-mercedes group vehicles.

    Technical characteristics:
    maximum nominal voltage: 32 Volts DC
    Use temperatures: -40 ° C to + 85 ° C.
    Good resistance to vibrations, shocks and corrosion

    consult us for any other request concerning the circuit breakers.

    We can notably provide automatic reset sheets fuses: after having confined to overheating or overvoltage, the circuit breaker fuse recovers when it cools.
    for difficult to access applications, when manual rearmament is not possible.
    ampèrage 15
    Catalog page 12.5